BCKNY - PROXON 19122
- MSDS: BCKNY
- Manufacturer: EUTECTIC CORP
- Product Name: PROXON 19122
- National Stock Number: 3439-00N003668
Product Identification
Product ID:PROXON 19122
MSDS Date:01/01/1985
FSC:3439
NIIN:00N003668
MSDS Number: BCKNY
Responsible Party
Emergency Phone: 212-358-4000
Cage: EO060
Contractor
Telephone: 704-527-9800/ 800-221-1433
Cage: EO060
Ingredients
CHROMIUM (SARA III)
CAS: 7440-47-3
RTECS: GB4200000
Fraction By Weight: 2.5%
OSHA PEL 1 MG/M3
ACGIH TLV: 0.5 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: >50%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: <1%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5 MG/M3(FE),B2; 9293
MOLYBDENUM
CAS: 7439-98-7
RTECS: QA4680000
Fraction By Weight: 2.5%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3; 9293
ALUMINUM (SARA III)
CAS: 7429-90-5
RTECS: BD0330000
Fraction By Weight: 2.5%
OSHA PEL 15MG/M3 DUST/5 FUME
ACGIH TLV: 10MG/M3 DUST; 9192
Hazards
Effects of Overexposure:VAPORS IN CONFINED AREA MAY BE HARMFUL.
First Aid
First Aid:INHALATION: REMOVE TO WELL VENTILATED AREA,OBTAIN MEDICAL
ASSISTANCE IF NECESSARY.
Accidental Release
Spill Release Procedures:NORMAL HOUSEKEEPING MAY BE VACUUM CLEANED.
Handling
Handling and Storage Precautions:REFER TO AWS C2.1-1973,RECOMMENDED
SAFE PRACTICES FOR THERMAL SPARYING.
Exposure Controls
Respiratory Protection:AIR SUPPLIED TYPE IN CONFINED AREA.
Ventilation:LOCAL EXHAUST
Eye Protection:GOGGLES./PROTECT SHIELD
Other Protective Equipment:REFER TO AWS PUBLICATION-AWS C2,1-1973.
Supplemental Safety and Health
ADD INGREDIENTS: CARBON <1%,TLV: 10 MG/CUM; BORON <1%,TLV:10MG/CUM;
SILICON <1%,TLV: 10 MG/CUM.
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:NORMAL INDUSTRIAL WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.